化工进展 ›› 2016, Vol. 35 ›› Issue (S1): 26-30.DOI: 10.16085/j.issn.1000-6613.2016.s1.005

• 化工过程与装备 • 上一篇    下一篇

水力喷射空气旋流器用于吸收处理工业尾气中的氨气

程治良, 全学军, 徐飞, 代明星   

  1. 重庆理工大学化学化工学院, 重庆 400054
  • 收稿日期:2015-11-11 修回日期:2015-12-13 出版日期:2016-06-30 发布日期:2016-07-08
  • 通讯作者: 程治良(1986-),男,博士,讲师,研究方向为特种废水、废气的处理。E-mail purper@cqut.edu.cn。
  • 基金资助:
    重庆市基础与前沿研究计划(cstc2015jcyjA20005)及重庆理工大学(2014ZD04,2014XH16)项目。

Ammonia absorption of chemical flues gas by acid solution in a water-sparged aerocyclone reactor

CHENG Zhiliang, QUAN Xuejun, XU Fei, DAI Mingxing   

  1. School of Chemistry and Chemical Engineering, Chongqing University of Technology, Chongqing 400054, China
  • Received:2015-11-11 Revised:2015-12-13 Online:2016-06-30 Published:2016-07-08

摘要: 针对工业尾气中氨气吸收存在的传质效率低、设备易于堵塞等问题,本文采用新型超重力气液传质设备水力喷射空气旋流器(WSA),以稀硫酸溶液为吸收剂,开展了氨气吸收处理研究。研究考察了初始NH3浓度、进口气速、喷孔面积以及中心排气管直径等操作参数和WSA结构参数对氨气吸收处理效率的影响。研究结果表明,NH3吸收率随着初始NH3浓度和进口气速的增大均呈现先增大后降低的规律。NH3吸收率随着WSA的喷孔面积的增大先增大后趋于平缓,但却随着WSA的中心排气管直径的增大而降低,但压降也随之增大。在NH3浓度为4500mg/m3左右,进口气速为26.46m/s时,采用喷孔面积为565.5mm2、中心排气管直径为32mm的WSA,NH3吸收去除率可达99.5%以上。该工艺在工业尾气中的NH3回收处理方面具有较大的应用前景。

关键词: 气体旋流器, 吸收, 气液两相流, 分离

Abstract: In order to overcome the disadvantage of low efficiency and serious scaling and clogging in traditional ammonia absorption process using packed beds as the absorber.In this paper, water-sparged aerocyclone (WSA), a new gas-liquid mass transfer equipment was used for ammonia absorption of chemical flues gas by dilute sulphuric acid solution.The effect of operation parameters of initial ammonia concentration, flues gas inlet velocity and WSA structure parameters of sparge hole area and diameter of vortex finder on ammonia absorption efficiency were investigated.The results showed that the ammonia absorption efficiency increased firstly and then decreased with the increase of initial ammonia concentration and flues gas inlet velocity.It increased fast at first and then tended to increase slowly with the increase of sparge hole area, however, it decreased with the increase of diameter of vortex finder.When initial ammonia concentration of 4500mg/m3, flues gas inlet velocity of 26.46m/s, using the WSA of sparge hole area of 565.5mm2 and diameter of vortex finder of 32mm, the ammonia absorption efficiency could be as high as more than 99.5%.These results provide a kind of alternative for ammonia absorption of chemical flues gas in chemical industry.

Key words: gas cyclone, absorption, gas-liquid flow, separation

中图分类号: 

京ICP备12046843号-2;京公网安备 11010102001994号
版权所有 © 《化工进展》编辑部
地址:北京市东城区青年湖南街13号 邮编:100011
电子信箱:hgjz@cip.com.cn
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn