化工进展 ›› 2023, Vol. 42 ›› Issue (5): 2586-2594.DOI: 10.16085/j.issn.1000-6613.2022-1345

• 材料科学与技术 • 上一篇    下一篇

Silicalite-1分子筛膜渗透蒸发条件的响应面分析与优化

赵尧(), 周志辉(), 吴红丹, 胡传智, 张国春, 吴睿鹏   

  1. 武汉科技大学资源与环境工程学院,湖北 武汉 430080
  • 收稿日期:2022-07-18 修回日期:2022-09-13 出版日期:2023-05-10 发布日期:2023-06-02
  • 通讯作者: 周志辉
  • 作者简介:赵尧(1996—),男,硕士研究生,研究方向为环境功能材料。E-mail:406453077@qq.com
  • 基金资助:
    2020年度湖北省教育厅科学技术研究计划指导性项目(B2020019)

Response surface analysis and optimization of membrane permeation vaporization by Silicalite-1 molecular sieve

ZHAO Yao(), ZHOU Zhihui(), WU Hongdan, HU Chuanzhi, ZHANG Guochun, WU Ruipeng   

  1. College of Resources and Environmental Engineering, Wuhan University of Science and Technology, Wuhan 430080, Hubei, China
  • Received:2022-07-18 Revised:2022-09-13 Online:2023-05-10 Published:2023-06-02
  • Contact: ZHOU Zhihui

摘要:

采用Silicalite-1分子筛膜用于低浓度乙醇/水溶液的渗透蒸发分离,运用单因素实验考察了晶种质量分数、晶化温度、晶化时间3个制备条件对Silicalite-1分子筛膜渗透蒸发分离性能的影响,借助响应面分析(RSM)研究了料液温度、乙醇质量分数、真空压力3个运行条件对分离系数和渗透通量的影响。单因素实验结果表明,在晶种质量分数为0.3%、晶化温度为175℃、晶化时间为7h条件下制备的Silicalite-1分子筛膜对乙醇/水的渗透蒸发分离效果较好。RSM结果表明,料液温度、料液配比、真空压力对分离系数和渗透通量的影响显著,根据RSM建立多项式模型并对该模型预测的最佳条件进行了实验验证,实验结果与模型预测较为吻合。在进料温度为70℃、乙醇质量分数为3.49%、真空压力为7.82kPa条件下,实际分离系数和渗透通量与预测值偏差分别小于5.46%和7.39%。

关键词: 分子筛, 渗透蒸发, 乙醇, 分离, 响应面分析

Abstract:

The pervaporation separation of low concentration ethanol/water solutions by Silicalite-1 molecular sieve membranes was studied. The effects of seed concentration, crystallization temperature and crystallization time on the pervaporation separation performance of Silicalite-1 molecular sieve membrane were investigated by single factor experiment. Response surface analysis (RSM) was used to study the effects of feed liquid temperature, ethanol concentration and vacuum pressure on the separation coefficient and permeate flux. The results of single factor experiments showed that the Silicalite-1 molecular sieve membrane prepared under the conditions of seed concentration 0.3%, crystallization temperature 175℃ and crystallization time 7h exhibited the preferable pervaporation separation of ethanol aqueous solutions. According to the RSM results,the separation coefficient and permeate flux were significantly affected by feed liquid temperature, feed liquid ratio, and vacuum pressure. A polynomial model was established according to RSM results and the optimal conditions of the model prediction were verified by experiments. At feed temperature of 70℃, ethanol concentration of 3.49%, and vacuum pressure of 7.82kPa, the deviations of the actual separation coefficient and permeate flux from the predicted values were less than 5.46% and 7.39%, respectively.

Key words: molecular sieve, pervaporation, ethanol, separation, response surface analysis

中图分类号: 

京ICP备12046843号-2;京公网安备 11010102001994号
版权所有 © 《化工进展》编辑部
地址:北京市东城区青年湖南街13号 邮编:100011
电子信箱:hgjz@cip.com.cn
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn