化工进展 ›› 2015, Vol. 34 ›› Issue (04): 1143-1146,1164.DOI: 10.16085/j.issn.1000-6613.2015.04.042

• 资源与环境化工 • 上一篇    下一篇

复频超声降解土霉素废水

程琛1, 闫正2   

  1. 1. 宿州学院资源与土木工程学院, 安徽 宿州 234000;
    2. 河北大学环境工程研究所, 河北 保定 071000
  • 收稿日期:2014-09-04 修回日期:2014-10-12 出版日期:2015-04-05 发布日期:2015-04-05
  • 作者简介:程琛(1986—),女,助教,硕士,主要研究方向为水污染控制.E-mail cc101209@126.com.
  • 基金资助:
    安徽省煤矿勘探工程技术研究中心平台项目(2014YKF05).

Degradation of oxytetracycline in wastewater by multi-frequency ultrasonic

CHENG Chen1, YAN Zheng2   

  1. 1. School of Resources and Civil Engineering, Suzhou University, Suzhou 234000, Anhui, China;
    2. Environmental Engineering Research Institute, Hebei University, Baoding 071000, Hebei, China
  • Received:2014-09-04 Revised:2014-10-12 Online:2015-04-05 Published:2015-04-05

摘要: 以抗生素土霉素为研究对象,采用自制复频超声波污水处理装置,通过正交实验探究超声频率、功率、超声作用时间和土霉素效价4个正交因子对去除率的影响,以及通过4组不同复频组合的超声实验,研究复频超声对土霉素去除率及COD去除率的影响.结果表明,各因素的影响权重:超声频率> 作用时间> 效价> 超声功率,超声频率对土霉素的降解起重要作用;高频复频组合条件下土霉素去除率和COD去除率比低频复频组合高,但高低频组合的复频20kHz+100kHz+200kHz条件下,土霉素去处效果最好;最佳复频组合条件下处理体积为40L的土霉素经30min复频超声作用,去除率接近100%,60 min COD去除率达90%以上.

关键词: 复频超声污水处理装置, 降解, 土霉素, 正交实验

Abstract: This research investigated degradation of oxytetracycline in wastewaterusing self-made sewage treatment device with multi-frequency ultrasonic. The ultrasonic frequency,power,ultrasonic time and titer four orthogonal factors' influence on oxytetracycline removal rate through the orthogonal experiment were evaluated. The influences of four different combinations of multi-frequency ultrasonic experiment on removal rates of oxytetracycline and COD were also studied. The results showed that the influencing factors were weighted as the following:ultrasonic frequency > ultrasonic time > titer > ultrasonic power. Ultrasonic frequency was very important in the degradation of oxytetracycline. Removal rates of both oxytetracycline and COD were higher under high-frequency combinations of multi-frequency ultrasonic. The degradation reached maximum when the multi-frequency combination was at 20kHz + 100kHz + 200kHz. Under this multi-frequency ultrasonic condition,the removal rate of oxytetracycline was close to 100% within 30 minutes and more than 90% of COD was removed within 60 at the processing volume of 40L.

Key words: multi-frequency ultrasonic device on sewage treatment, degradation, oxytetracycline, orthogonal experiment

中图分类号: 

京ICP备12046843号-2;京公网安备 11010102001994号
版权所有 © 《化工进展》编辑部
地址:北京市东城区青年湖南街13号 邮编:100011
电子信箱:hgjz@cip.com.cn
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn