化工进展 ›› 2016, Vol. 35 ›› Issue (05): 1555-1560.DOI: 10.16085/j.issn.1000-6613.2016.05.044

• 应用技术 • 上一篇    下一篇

利用氢气分离膜降低乙烯深冷系统制冷压缩机的功耗

周天宇, 阮雪华, 陈博, 张元夫, 肖武, 贺高红   

  1. 大连理工大学膜科学与技术研究开发中心, 辽宁 大连 116024
  • 收稿日期:2015-09-01 修回日期:2015-09-14 出版日期:2016-05-05 发布日期:2016-05-05
  • 通讯作者: 贺高红,教授,博士生导师,主要研究膜科学与技术、生物医学工程。E-mail hgaohong@dlut.edu.cn。
  • 作者简介:周天宇(1991-),男,硕士研究生,主要研究气体膜分离。
  • 基金资助:
    国家自然科学基金(21206014,21125628)及中央高校基本科研业务费专项资金项目(DUT14LAB14)。

Reducing refrigeration compressor power in chilling process of ethylene plant by using hydrogen separation membrane

ZHOU Tianyu, RUAN Xuehua, CHEN Bo, ZHANG Yuanfu, XIAO Wu, HE Gaohong   

  1. Membrane Science and Technology R&D Center, Dalian University of Technology, Dalian 116024, Liaoning, China
  • Received:2015-09-01 Revised:2015-09-14 Online:2016-05-05 Published:2016-05-05

摘要: 针对传统乙烯过程中深冷脱氢工艺冷凝温度低、能耗大的问题,基于某800kt/a乙烯的裂解气脱氢装置,提出了两级膜与深冷耦合回收乙烯裂解气中氢气的流程,利用UniSimDesign软件对新流程进行了模拟分析,确定了两级膜面积分别为28000m2和10110m2。由于第一级膜分离装置回收了裂解气中的部分氢气,显著地减少了深冷系统中制冷压缩机的功耗和脱甲烷塔塔顶的乙烯损失,新流程深冷系统的制冷压缩机功耗为39496kW,比原流程减少了8996kW,乙烯损失率由1.29%降低到0.46%。第二级膜分离装置实现了氢气回收的高纯度(99%)和高回收率(98.52%),获得的氢气产品可以直接并入氢网或用于对氢气浓度要求较高的加氢裂化装置中。

关键词: 氢气分离膜, 乙烯裂解气, 计算机模拟, 节能, 优化设计

Abstract: The chilling process of traditional ethylene process has several disadvantages, including low condensation temperature, which requires significant amount of energy. To recover hydrogen from an ethylene plant of 800 kt/a, a hybrid process combining two-stage hydrogen separation membrane and cryogenics was proposed. Based on simulation and optimization with the UniSim Design software, the optimal conditions of this membrane system were identified, i.e, membrane areas in two stages were 28000m2 and 10110m2, respectively. In conclusion, refrigeration compressor power and ethylene loss were significantly decreased because part of hydrogen was recovered by the first-stage membrane system. The compressor power in the chilling process was 39496kW, 8996kW lower than that in the traditional process. The ethylene loss of demethanizer overhead decreased from 1.29% to 0.46%. H2 product with high concentration (99%) and high recovery (98.52%) was achieved through the second-stage membrane system, which could merge into hydrogen network directly or be used for hydrocracking with higher demand for hydrogen concentration.

Key words: hydrogen separation membrane, ethylene cracked gas, computer simulation, energy conservation, optimal design

中图分类号: 

京ICP备12046843号-2;京公网安备 11010102001994号
版权所有 © 《化工进展》编辑部
地址:北京市东城区青年湖南街13号 邮编:100011
电子信箱:hgjz@cip.com.cn
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn