化工进展 ›› 2021, Vol. 40 ›› Issue (S2): 25-29.DOI: 10.16085/j.issn.1000-6613.2021-0906

• 化工过程与装备 • 上一篇    下一篇

330MW锅炉配风方式对NOx排放浓度和锅炉经济性的影响分析

白旭东(), 王建勋   

  1. 国能龙源蓝天节能技术有限公司,北京 100039
  • 收稿日期:2021-04-27 修回日期:2021-05-13 出版日期:2021-11-12 发布日期:2021-11-12
  • 通讯作者: 白旭东
  • 作者简介:白旭东(1970—),男,高级工程师,研究方向为火电机组优化运行和节能减排技术等。E-mail:wangjx307@163.com

Experimental research of influence of air distribution for a W-flame boiler on NOx emission and economical operation

BAI Xudong(), WANG Jianxun   

  1. CHN Energy Long Yuan Blue Sky Energy Conservation Technology Co. , Ltd. , Beijing 100039, China
  • Received:2021-04-27 Revised:2021-05-13 Online:2021-11-12 Published:2021-11-12
  • Contact: BAI Xudong

摘要:

针对某电厂330MW锅炉进行了配风方式及总风量的研究,分析了配风方式及总风量的变化对NOx排放浓度和锅炉经济性的影响。结果表明:在机组负荷一定的条件下,改变配风方式,当机组负荷为250MW时,工况T2与工况T1的锅炉效率相差不多,NOx排放浓度下降了40mg/m3;当机组负荷为300MW时,工况T4比工况T3的锅炉效率高了0.28%,NOx排放浓度下降了20mg/m3。在机组负荷及其他运行参数基本不变的条件下,改变总风量,当机组负荷为300MW时,工况T6比工况T5的锅炉效率高了0.19%,NOx排放浓度下降了40mg/m3;当机组负荷为250MW时,工况T9比工况T7的锅炉效率高了0.16%,NOx排放浓度升高了40mg/m3。当机组负荷为190MW时,工况T12比工况T10的锅炉效率高了0.24%,NOx排放浓度下降了60mg/m3

关键词: 配风方式, 总风量, NOx排放浓度, 锅炉经济性, 锅炉效率

Abstract:

Research of mode of air distribution and total air volume for a 330MW boiler in a certain power plant,were carried out to analysis the influence of mode of air distribution and total air volume variation on concentration of NOx emission and economical operation of the boiler. Result of the test showed that under the constant Unit load, change the air distribution mode, under 250MW load, the efficiency of the boiler at working condition T2 is similar to that of the boiler at working condition T1, concentration of NOx emission decreased by 40mg/m3, under 300MW load, the efficiency of the boiler at working condition T4 is 0.28% higher than that of the boiler at working condition T3, concentration of NOx emission decreased by 20mg/m3.Under the condition that the unit load and other operation parameters are basically invariable,change the total air volume,under 300MW load, the efficiency of the boiler at working condition T6 is 0.19% higher than that of the boiler at working condition T5, concentration of NOxemission decreased by 40mg/m3. Under 250MW load, the efficiency of the boiler at working condition T9 is 0.16% higher than that of the boiler at working condition T7, concentration of NOxemission increased by 40mg/m3. Under 190MW load, the efficiency of the boiler at working condition T12 is 0.24% higher than that of the boiler at working condition T10, concentration of NOx emission decreased by 60mg/m3.

Key words: mode of air distribution, total air volume, concentration of NOx emission, economical operation of the boiler, efficiency of the boiler

中图分类号: 

京ICP备12046843号-2;京公网安备 11010102001994号
版权所有 © 《化工进展》编辑部
地址:北京市东城区青年湖南街13号 邮编:100011
电子信箱:hgjz@cip.com.cn
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn