Chemical Industry and Engineering Progree ›› 2012, Vol. 31 ›› Issue (04): 933-937.

Previous Articles     Next Articles

  Differential thermal analysis during the thermal decomposition of three typical medical wastes

  MA HongtingWANG FangchaoYANG GuoliHAO SufengWANG Minghui   

  1. School of Environmental Science and Technology,Tianjin University,Tianjin 300072,China
  • Received:2011-10-09 Revised:2011-10-27 Online:2012-04-05 Published:2012-04-05

  三种典型医疗废物热解过程的差热分析

  马洪亭,王芳超,杨国利,郝夙枫,王明辉   

  1. 天津大学环境科学与工程学院,天津 300072
  • 通讯作者: 马洪亭

Abstract:   The thermal decomposition and differential thermal analysis process of three typical medical wastes(infusion bag,toilet paper,injector)were experimentally investigated by using the TG-DTA apparatus,the samples were heated at 20℃/min in 20 mL/min nitrogen flow. The results show that the thermal decomposition of medical waste is a heat-absorption process. The curve shape is complex,and non-symmetric. There is a significant deviation in base line. The temperature for the maximum weight loss rate is lower than that for the instantaneous thermal balance.

Key words:  ,

摘要:   用TG-DTA差热热重联用分析仪在升温速率为20 ℃/min、高纯氮气流量为20 mL/min的气氛条件下对输液袋、卫生纸和注射器3种典型医疗废物试样进行了热解实验和差热分析。结果表明,几种试样热解过程均为吸热反应,而且实验测得的DTA曲线的形状比较复杂,对称性较差,基线偏移较大;在医疗废物的热解过程中,最大失重速率发生点的温度一般要比达到瞬时热平衡点的温度稍低。